 |  | PAVAN Shell and Tube Heat Exchanger fitted with centrifugal pump This shell and tube heat exchanger was used in a pasta plant.It comes fitted with its own centrifugal pump
No name on pump
Motor size of pump: 2.2kW 2855 rpm
Grade of s/s: 304 /304L
Tube Length: 1500mm
No of Tubes: (To be advised on opening the unit)
OD of Shell tube: 300mm
Stamp on Pump Inlet Flange WA 052268 BE 967
Stamp on flange leading to HE from Pump
65DN -10 16 Tube1092 F 304/304L ... |  |  | SEIKENSHA Continuous Cooker/Extractor This system mixes and cooks by utilising a stainless steel screw driving through a steam jacketed S/S barrel.
Solids enter the system via an overhead mounted feed hopper via an adjustable feed rate "gate" valve.
A facility exists for a liquid addition to the screw barrel, immediately following the solids entry point. The liquid feed is via an on board S/S 1/2" pump and 1/2" thick wall tubing. ... |  |  | IOPAK Cream Chiller Capacity 1,000L/Hr
Tank Capacity: 300L
Product Contact: SUS316 (SUS304 for Non-Contact)
Cream Inlet Temperature 36 °C
Flow Temperature 36°C- 4 °C
It is equipped with 1.5" Rotary Lobe Pump (1,000L/hr) -
This cream cooler will be supplied to Australian Standards. It will be skid mounted. ... |  |  | ALFA LAVAL Heat Exchanger for Hot Water ... |  |  | HYPEX Heat Exchanger Tube
Length: 6m ... |  |  | MGC Holding Tubes (s/s) This 10 pass holding tube was used in a water treatment plant in a dairy.
Tube Diameter: 80mm
Number of passes 10
Length of each pass: 3300mm
Capacity: Approx 26³m capacity
Tubes are mounted on a sturdy set of 700mm wide legs.
Overall height of Unit: 2250mm ... |  |  | JOHNSON Horizontal scraped surface heat exchanger The unit was previously used for texturisation of chocolate paste.
Name Plate Details -
JACKET SIDE
Design Press (N/mm) 1.379²
Hydraulic Test Press (N/mm) 2.07²
Design Temp (Deg C) 195
Cap (Litres) 11.51
Medium Water
PRODUCT SIDE
Design Press (N/mm) 3.45²
Hydra ... |  |  | HOTCO In- Line Heat Exchanger (Electric) This system is designed to heat pure water that flows through the unit, from 0 degrees C up to 130 degrees C (under pressure) The unit comprises a free standing in- line electric heat exchanger and an electrical control panel :-
Fluid: Pure Water
Temperature: 100 degrees C
Power Rating: 200Kw, plus 10%, 415V, 50Hz
Minimum Rating: 66kW
DELTA, (3 x 66kW Zones)
Heating System:
Eighteen (18) ... |  |  | JOHNSON VOTATOR Laboratory Scraped Surface Heat Exhanger This laboratory/pilot scale scraped surface heat exchanger, or continuous cooker, was used in the confectionery industry. ... |  |  | AUSMADE (Australian Made) Stainless Steel Heat Exchanger This unit consists of 10 spiral formed 25mm dia stainless steel tubes of 3,000mm length set in a flat rack configuration. Centre distance between the tubes is 85mm and the entry and exit ports are 1.5" female dairy.
The unit would be suitable for ambient air interchange or as liquid submersed type heat exchanger. ... |  | |
|
|
|
|